Gira electronic blind controller 2

A convenient timing function can be incorporated into the automatic blind control system with the electronic blind controller 2. At the touch of a button, the times at which the blinds or roller shutters should be set in motion can be specified. If desired, the integrated Astro program will factor in the different sunrise and sunset times throughout the year. And when the home's occupants are away on holiday, the random generator controls the blinds at a different time each day. 

The electronic blind controller 2 also allows a blind control system to be set up to manage central commands per floor or for the whole building. As a result, blinds can be moved individually or all simultaneously from a central point.

Settings and functions

Certain switching times are factory-preset for a quick start-up. A total of 9 UP and 9 DOWN switching times per day can be programmed within 3 program memory spaces. The Astro program, which factors in changing sunrise and sunset times, can reschedule the activation of the blinds by +/- 2 hours. When the random generator is used for times of absence, this becomes +/- 15 minutes. The switch to summer time or winter time is automatic. 

The 23 x 40 mm LCD display shows all the information: the next movement time of the blind(s), day of week, time, status of the Astro program, summer time or winter time, as well as whether the random generator is active or not. The power reserve is up to 4 hours.

Blind controller insert without auxiliary input

  • Motor protection through mechanically interlocked relay contacts with a minimum switching time of 1 second
  • Rated voltage: 230 V, 50 Hz, N conductor required
  • Switching capacity: max. 1000 VA
  • Relay output: 2 NO contact relays
    (non-isolated and mechanically interlocked)

Blind controller insert with auxiliary input

  • Mechanical buttons or additional blind controller inserts can be connected via
    230 V auxiliary inputs to set up group controls
  • 'Wind alarm function' can be realised via auxiliary inputs
  • Motor protection through mechanically interlocked relay contacts with a minimum switching time of 1 second
  • Rated voltage: 230 V, 50 Hz, N conductor required
  • Switching capacity: max. 1000 VA
  • Relay output: 2 NO contact relays
    (non-isolated and mechanically interlocked)
The delivery results subject to countries specific assortments