Gira wireless control unit 1–10 V, 1-gang DRA

Fluorescent lamps with 1–10 V electronic ballasts and electronic transformers with 1–10 V control input can be switched or dimmed using the Gira wireless control unit 1–10 V. Special features: Soft start for longer lamp life and a memory function (brightness memory).

Technical data

Rated voltage

AC 230 V, 50 Hz

Control voltage

1 to 10 V

Connected load

2300 W ohmic load type-dependent electronic ballast

Control current

max. 200 mA

Ambient temperature

+50°C

Protection typet

IP 20

Dimensions

L x W x H 175 x 42 x 18 mm

The delivery results subject to countries specific assortments