A “reset” returns the controller to its delivery status. To do this, press the + (plus) and - (minus) buttons at the same time for more than 10 seconds. Following this, a display test is automatically carried out. The date and time for initial start-up can be set.
Notes:
Devices with no index label (e.g. RTR top unit with clock, item no. 0389 xx)
In the case of devices with no index label, the rate deviation factor must be noted before performing the reset. You can find this factor on the back of the top unit. Once you have programmed the time and date, set the rate deviation as follows:
- Press Set and Prog at the same time for approx. 10 seconds. “n” flashes and then the clock appears, target or actual. (Time is factory-set)
- Press the “Plus” button ten times until a flashing “U” appears.
- Press Set to select and set the desired value using the plus or minus button.
Devices with index label (e.g. RTR top unit with clock, item no. 0389 xx) index: I00)
In the case of devices with an index label, the rate deviation correction factor is permanently stored in the EEPROM.
The room temperature controller with clock does not have a general switch-off function. You can, however, permanently switch it from automatic mode to the lowering temperature (moon symbol).
To do this, press the “-” button for around 5 seconds. The temperature level indicator will then change to the moon symbol (= lowering temperature) and the indicator in front of the clock symbol will go out.
To return the room temperature controller with clock to automatic mode, briefly press the Prog. button.
The “55” refers to the rectangular dimensions of the rockers, covering panels and socket outlets (55x55 mm). The System 55 platform allows you to use over 300 functions and offers a wide range of colours and designs across seven design lines (Gira Standard 55, E2, E3, Event, Esprit, ClassiX, and Studio). The Standard 55 designation here is an additional reference to the Gira Standard frame range, which has the same dimensions.
Yes this is possible as the timer has a zero-voltage contact and the neutral conductor is activated on the room temperature controller for a night-time reduction.
The TX_44 and water-protected surface-mounted (WP SM) ranges are ideally suited for outdoor use. The TX_44 range offers IP44 protection and the WP SM offers protection up to IP66. The Standard 55 and E2 ranges also offer IP44 protection on the basis of the socket outlets, rocker switches and rocker buttons with seal set.